IE2000U with 16FE Copper, 2GE + 2FE Combo (Lan Base) – CC
IE-2000U-16TC-G-X Specification |
|
Total Ports |
20 |
RJ45 Ports |
16 FE |
Combo Ports |
2 GE + 2 FE |
Software |
LAN Base |
IEEE 1588 |
Yes |
PRP |
Yes |
Dimensions (H x W x D), Including DIN Rail |
5.1 x 5.0 x 5.26 in (130 x 127 x 134 mm) |
Weight |
4.35 lbs (1.97 kg) |
Hardware |
● 256 MB DRAM with ECC memory ● 1 GB removable SD flash memory card (CG swap drive) – (128MB space available) ● Mini-USB connector |
Alarm |
● Alarm I/O: two alarm inputs to detect dry contact open or closed, one alarm output relay. 48 VDC, 0.5A max |
Power Supply |
● Redundant DC input voltage with operating range: 12-48 VDC Nominal, 9.6-60 VDC Maximum ● Maximum DC input current: 0.5A at 48 VDC, 1A at 24 VDC |
Power Consumption |
20-port models: 13-20 W |
Substation Compliance |
● IEC 61850-3 ● IEEE1613 |
Hazardous Location |
● ANSI/ISA 12.12.01 (Class 1, Div 2 A-D) (requires cabinet enclosure) ● UL/CSA 60079-0, -15 (Class 1, Zone 2, group II gases, requires cabinet enclosure) ● EN 60079-0, -15 ATEX certification (Class I, Zone 2, Group II gases, requires cabinet enclosure) ● IEC 60079-0, -15 (Class I Zone 2, Group II gases, requires cabinet enclosure) ● CSA 213 |
Industrial Control Safety |
● UL508 ● CSA C22.2 No. 142 |
EMC Interface Immunity |
● EN 55024 (CISPR 24) ● AS/NZS CISPR 24 ● KN 24 ● IEC61000-4-2 (Criteria A – Class 2) ● IEC61000-4-3/ENV50204 (Criteria A) ● IEC61000-4-4 (Criteria A/Criteria B) ● IEC61000-4-5 (Criteria B) ● IEC61000-4-6 (Criteria A) |
Standard Electromagnetic Emissions Certifications |
● FCC Part 15 Class A ● EN 55022 Class A (CISPR22 Class A) ● ICES-003 Class A ● EN 300 386 ● VCCI Class A ● AS/NZS CISPR22 Class A ● CNS 13438 Class A ● KN 22 Class A CE Marking |
Standard Safety Certifications |
● UL 60950-1 ● CSA 60950-1 ● EN 60950-1 ● IEC 60950-1, CB report and certificate with all national differences |
Operating Environment |
● Operating Temperature: -40C to +75C ● -40C to +70C (Vented Enclosure – 40 LFM Air Flow) ● -40C to +60C (Sealed Enclosure – 0 LFM Air Flow) ● -34C to +75C (Fan or Blower equipped Enclosure – 200 LFM Air Flow) ● -40 to +85C (IEC 60068-2-2 Environmental Type testing – 100 hours) ● Operating altitude: -60 m (-200 ft) to 3,000 m (10,000 ft), de-rate maximum operating temperature per IEEE 1613-2009: ● Relative humidity: 5% to 95% non-condensing |
Storage Environment |
● Temperature: -50º C to +85º C ● Altitude: 15,100 ft (4600 m) |
Warranty |
● Five-year limited warranty on all IE-2000U HW PIDs |
Mean Time Between Failure (MTBF) |
● 535,190 Hours |
Protection Class Code |
● IP30 per EN60529 |