Nexus 31128PQ, 96 SFP+ ports, 8 QSFP+ ports, 2RU switch
N3K-C31128PQ-10GE Specification |
||
Physical |
· 2RU fixed form-factor switch · 8 QSFP+ ports · 96 SFP+ ports · 2 redundant power supplies · 2 redundant (1+1) fans (2 rotors per fan) · Management, console, and 2 USB flash-memory ports |
|
Performance |
· 2.5 Tbps switching capacity · Forwarding rate up to 1.4 bpps · Line-rate traffic throughput (both Layer 2 and 3) on all ports · Configurable maximum transmission units (MTUs) of up to 9216 bytes (jumbo frames) |
|
Hardware tables and scalability |
Number of MAC addresses |
288,000 |
Number of VLANS |
4096 |
|
Number of spanning-tree instances |
· RSTP: 512 · MSTP: 64 |
|
Number of access control list (ACL) entries |
4000 ingress 1000 egress |
|
Routing table |
· 16,000 prefixes and 16,000 host entries · 8000 multicast routes |
|
Number of EtherChannels |
64 (with vPC) |
|
Number of ports per EtherChannel |
16 |
|
Buffer size |
12 MB shared |
|
Boot flash memory |
64 GB SSD |
|
Power |
Frequency |
50 to 60 Hz |
Power supply types |
· AC (forward and reversed airflow) · DC (forward and reversed airflow) |
|
Typical operating power |
148 watts (W) |
|
Maximum power |
413 watts (W) |
|
AC PSUs · Input voltage · Frequency · Efficiency |
· 100 to 240 VAC · 50 to 60 Hz · 89 to 91% at 220V |
|
DC PSUs · Input voltage · Maximum current (PSU output – System input) · Efficiency |
· -40 to -72 VDC · 78A · 85 to 88% |
|
Power-supply efficiency |
89 to 91% at 220V |
|
Typical heat dissipation |
505 BTU/hr |
|
Maximum heat dissipation |
1409 BTU/hr |
|
Cooling |
· Forward and reversed airflow schemes ◦ Forward airflow: Port-side exhaust (air enters through fan tray and power supplies and exits through ports); supported with AC and DC power supplies ◦ Reversed airflow: Port-side intake (air enters through ports and exits through fan tray and power supplies); supported with AC power supply only · Redundant fans · Hot swappable (must swap within 1 minute) |
|
Sound |
Measured sound power (maximum) · Fan speed: 40% duty cycle · Fan speed: 70% duty cycle · Fan speed: 100% duty cycle |
· 66.1 dBA · 70.6 dBA · 76.9 dBA |
Environment |
Dimensions (height x width x depth) |
3.39 x 17.40 x 23.70 in. (8.6 x 44.2 x 60.2 cm) |
Weight |
22.2 lb (10.1 kg) |
|
Operating temperature |
32 to 122°F (0 to 50°C) |
|
Storage temperature |
-40 to 158°F (-40 to 70°C) |
|
Operating relative humidity |
· 10 to 85% noncondensing · Up to 5 days at maximum (85%) humidity · Recommend ASHRAE data center environment |
|
Storage relative humidity |
5 to 95% noncondensing |
|
Altitude |
0 to 10,000 ft (0 to 3000m) |