Huawei CloudEngine S5736-S Series Multi-GE Switches S5736-S24UM4XC – 24 x 100M/1G/2.5G/5G/10G Base-T Ethernet ports, 4 x 10 GE SFP
S5736-S24UM4XC Specification |
|
Item |
Specification |
Dimensions without packaging (H x W x D) [mm(in.)] |
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 448.0 mm (1.72 in. x 17.40 in. x 17.64 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] |
150mm × 710mm × 560mm (5.90 in. x 27.95 in. x 22.05 in.) |
Chassis height [U] |
1 U |
Typical power consumption [W] |
117 W |
Typical heat dissipation [BTU/hour] |
399.22 BTU/hour |
Maximum power consumption [W] |
|
Maximum heat dissipation [BTU/hour] |
|
MTBF [year] |
59.44 year |
MTTR [hour] |
2 hour |
Availability |
>0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] |
70.1 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] |
58.1 dB(A) |
Number of card slots |
1 |
Number of power slots |
2 |
Number of fans modules |
2 |
Redundant power supply |
1 1 Pluggable AC and DC power modules can be used together in the same switch. |
Long-term operating temperature [°C(°F)] |
-5°C to 45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) |
Short-term operating temperature [°C(°F)] |
-5°C to 50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met:
If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur. Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation cannot exceed 10 km. |
Storage temperature [°C(°F)] |
-40°C to 70°C (-40°F to 158°F) |
Long-term operating relative humidity [RH] |
5% to 95%, noncondensing |
Long-term operating altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
Storage altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
Power supply mode |
Pluggable power supply |
Rated input voltage [V] |
|
Input voltage range [V] |
|
Maximum input current [A] |
The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules. |
Memory |
2 GB |
Flash memory |
1 GB in total. To view the available flash memory size, run the display version command. |
Console port |
RJ45 |
Eth Management port |
RJ45 |
USB |
Supported |
RTC |
Supported |
RPS input |
Not supported |
Service port surge protection [kV] |
Common mode: ±6 kV |
Power supply surge protection [kV] |
|
Types of fans |
Pluggable |
Heat dissipation mode |
Heat dissipation with fan, intelligent fan speed adjustment |
Airflow direction |
Air intake from left,front and right, air exhaustion from behind |
PoE |
Supported |
Certification |
EMC certification Safety certification Manufacturing certification |